:: EMC STECH ::
 
  HOME> Á¦Ç°¼Ò°³ > Adhesive force measuring method
 
   
180¡Æ Peel adhesion

¡Ü Specimen
¨ÍThe specimens shall be conditioned for at least three ours at standard temperature of
23¡É¡¾2¡É and at 50¡¾5 percent RH in accordance with KS A 0006.
¨ÎCut each 3 by about 250 mm long as original width in case width is less than 25 mm
at central of tape and sheet in case width of tape and sheet is more than 25 mm.
¨ÏCut to sharp knife lest edge region of specimen should be wounded.
¨ÐAdhesive side shall be clean and free of dirty, foreign matter, and indentation.

¡Ü Test equipment.
Use Tensile tester prescribed to KS B 5521.

¡Ü Test plate.
¨ÍTest plate uses STS 304 prescribed to KS D 3698.
¨ÎTest plate¡¯s size thickness more than 2 mm, widths are about 50 mm, lengths are about 125 mm
and 50 mm of test plate length direction one end mark 4 places from point to same space of 20 mm.
¨ÏSolvent for test plate¡¯s washing does by diacetonealcohol(4 hydroxy-4 methyl-2 pentanone),
isopropyl alcohol, ethanol, methanol, methylethylketone, acetone, acetylethyl, toluene, n-hexane,
gasoline.

¡Ü Compression device.
¨ÍUse auto or passivity unit and compress specimen by roller's weight.
¨ÎRoller is the surface spring hardness 85¡¾5Hs prescribed KS M 6784, width coated by rubber layer
of thickness about 6 mm are about 45 mm, diameter (rubber layer inclusion) about 95mm,
weight 2000¡¾50g.



¡Ü Test procedure.
¨ÍSpecimen puts in test plate's center within 15 seconds after picking, and attention lest air should be inserted.
¨ÎCompress specimen with the fixed compression speed and number of times.


Compression speed
About 5 mm/s
About 20 mm/s
Compression No. of time
1th round trip
2th round trip


¨ÏTest plate that attached specimen stations more than 5 minutes in temperature 23¡Æ¡¾ 2¡Æ¡¦, of RH 50% state.
¨ÐAfter have bent remained part of specimen by 180 degrees and take off about 40 mm, test plate¡¯s
end to down bite, remained part of specimen inserts to upper bite
¨Ñ Bent specimen attention to be run parallel on side that attach tape.
¨Ò Pull being successive with speed of 300 mm/s and measure 4 points to 20 mm space.





¡Ü Result.
Result records mean value of 12 points that measure by 3 specimen, and unit is N/10mm.

 
 
scroll on